SKMECHA01 MECH
WARNING! ENSURE PUMP IS ISOLATED FROM
ELECTRICITY AND WATER SUPPLY. IF IN
DOUBT CONSULT A COMPETENT
TRADESMAN.
Pump should be serviced in horizontal
position with couples disconnected and water
and electricity supply isolated.
DO NOT RUN PUMP DRY. ALLOW WATER TO
FILL PUMP TO LUBRICATE SEALS BEFORE
STARTING. CHECK FOR LEAKS DURING TEST
BEFORE BEING SATISFIED PUMP IS OK
PLEASE NOTE:
By using the parts included in this pack to repair your pump, you will
be invalidating any warranty you have on the pump.
Returns:
If you need to return this pack for any reason please ensure the
original packaging and these instructions leaflets are returned also.
If you have any questions or queries regarding this spares pack or
any other pump related questions please contact us.
UK:
Salamander Pumped Shower Systems Limited
Unit 2c, Colima Avenue Enterprise Park West
Sunderland SR5 3XE
Tel: 0191 516 2002
Email: tech@salamanderpumps.co.uk
Eire:
MTA agencies Ireland Fearn House,
Unit 4 Jamestown Business Park
Jamestown Road Finglas,
Dublin 11
Tel: +353 (0)1 864 3363
Email: service@mtagencies.ie
Salamander Pumps Shower Systems Limited
Unit 2c Colima Avenue, Enterprise Park West,
Sunderland, SR5 3XE
Telephone: 0191 516 2002
Facsimile: 0191 548 4445
Email: sales@salamanderpumps.co.uk
www.salamanderpumps.co.uk
Instructions VIDEOLINK:
Document SSI.10 December15. Issue 1
INTRODUCTION
All CT pump variants
Tools required :
Pliers
Seal Tool - XTOOLS 01
M6 Allen bit/Wrench
Torque Driver
Soap Water Solution 5%
Parts in Service kit:
Rotary Seal 10mm - SROTAR02 (14) x 2
Static Seal 10mm - SSTATI02 (13) x 2
Body O ring 59.6 mm OD - SORING17 (BOR)
Blue EPDM (17) x 2
Wire Clip- FWIREC01 (16) x 2
5. M6 Allen Bolt M6 X 45mm - FBOLTM04 (20)
x 8
M6 Spring Washer- FWASHE03 (21) x 8
Filter Washer-SFILTE01 (26) x 2
Rubber Washer-SFLATW01(25) x2
Seal Tool - XTOOLS01

Other manuals for Salamander Pumps CT Series

Questions and Answers

  • Q
    qschultzAug 3, 2025
    Why is my Salamander Pumps CT Water Pump not starting?
    • A
      Amanda FordAug 3, 2025
      Your Salamander Pumps Water Pump might not start due to several reasons: * Insufficient gravity flow: Verify the pump's suitability for your setup, ensuring it's not in a negative head installation. Check that the inlet filters are not blocked and that the flow rate meets the minimum requirement of 2l/min on both hot and cold water supplies. * Incorrect inlet/outlet connections: Make sure the connections are plumbed correctly and all valves are open. * Electrical issues: Check the power supply, fuse, and circuit breaker. * Debris under the flow switch: Remove the outlet hoses to check that the flow switch is in its lowest position. * Float sticking in the outlet: Ensure there's no debris in the outlet area.
  • R
    Robert ParrishAug 16, 2025
    Why is Salamander Pumps CT Water Pump noisy?
    • M
      Michaela ClarkAug 16, 2025
      A noisy Salamander Pumps Water Pump can be attributed to: * Air in the system: Refer to the instructions for dealing with air in the system. * Pump vibrating on the surface: Ensure the rubber feet are fitted to the pump. * AV couplers causing vibration: Check that all AV couplers are straight and not bent or distorted.
  • T
    thompsonleeAug 21, 2025
    What to do if Salamander Pumps CT Water Pump starts with all outlets closed?
    • R
      Robert OrtizAug 21, 2025
      If your Salamander Pumps Water Pump starts when all outlets are closed: * Check for leaks in the system. * Ensure all outlets are fully closed or capped, and there are no dead legs in the pipework.
  • B
    Brooke SpenceAug 28, 2025
    Why is my Salamander Pumps CT leaking?
    • V
      Vanessa AndersonAug 28, 2025
      If your Salamander Pumps Water Pump is leaking, consider these potential causes: * Pump exposed to mains water pressure: Fit a break cistern or remove the pump from the mains supply. * Pump suffered chemical damage: Ensure the pump hasn't come into contact with chemical substances like solder flux. * Pump exposed to excessive temperature: Check if effective temperature control is fitted (cylinder thermostat or HWS/TMV valve). * Unsure if the pump is leaking: Verify the leak isn't coming from a fitting in the pipework above the pump.
  • M
    Megan LutzNov 9, 2025
    What to do if Salamander Pumps CT Water Pump has reduced or intermittent flow?
    • C
      Christopher HernandezNov 9, 2025
      If your Salamander Pumps Water Pump experiences reduced or intermittent flow, consider the following: * Incorrect or missing anti-aeration flange: Fit the appropriate anti-aeration flange. * Insufficient gravity flow: Refer to the instructions for checking gravity flow. * Blocked inlet filters: Ensure all filters and the shower head are free from debris. * Couplers restricting flow: Make sure all AV couplers are straight and not bent or distorted. * Air in the system: Run the system on full hot with the pump switched off (gravity only) for several minutes. Check the cold water storage and refill rate, and ensure vents are fitted as instructed. * Wrong size pump: Verify the pump's capacity is sufficient for the equipment. * Hot temperature set too high: Reduce the cylinder th...

Summary

Service Kit General Information

Safety Precautions and Warnings

Highlights critical safety instructions, including electrical and water isolation, and pump handling.

Service Kit Contents

Lists all the genuine parts included in the service kit for pump repair.

Required Tools for Service

Specifies the tools and solutions needed to perform the pump service correctly.

Pump Service Procedure

Disassembly and Seal Replacement

Detailed steps for dismantling the pump, removing old seals, and installing new ones.

Reassembly and Final Testing

Guidance on reassembling the pump, fitting new parts, and preparing for operational testing.

Salamander Pumps CT Series Specifications

General IconGeneral
BrandSalamander Pumps
ModelCT Series
CategoryWater Pump
LanguageEnglish

Related product manuals