Pump installation and warranty
guide for the CT range of pumps
CT Force, CT Xtra, and CT Bathroom
ISSUE H
JAN 2019
Models shown:
CT FORCE 15TU
CT50 Xtra
CT60B

Questions and Answers

  • J
    Julie MooreAug 10, 2025
    What to do if Salamander Pumps Water Pump has reduced or intermittent flow?
    • S
      samanthazimmermanAug 10, 2025
      Reduced or intermittent flow in your Salamander Pumps Water Pump can stem from various factors. Make sure that all filters and the shower head are free from any obstructions. It's also important to ensure that all AV couplers are straight, not bent or distorted, as this can restrict flow. If these steps don't resolve the issue, review the other potential causes and solutions.
  • E
    Emma ClarkAug 15, 2025
    How to troubleshoot Salamander Pumps CT Force that will not start?
    • H
      Holly ClarkAug 15, 2025
      If your Salamander Pumps Water Pump won't start, begin by checking the power supply, fuse, and circuit breaker to rule out any electrical issues. Also confirm that the inlet and outlet connections are plumbed correctly and that all valves are open. Next, verify that the inlet filters are not blocked and that the flow rate meets the minimum requirement of 2l/min on both hot and cold supplies.
  • B
    Brandon EvansAug 20, 2025
    Why is my Salamander Pumps CT Force so noisy?
    • M
      Matthew AndersonAug 20, 2025
      If your Salamander Pumps Water Pump is noisy, make sure rubber feet are fitted to the pump to reduce vibration on the surface. Also, ensure that all AV couplers are straight and not bent or distorted, as they can cause vibration. Review the other potential causes and solutions.
  • J
    Justin DavisAug 26, 2025
    What to do if Salamander Pumps CT Force starts with all outlets closed?
    • K
      Kevin KellerAug 26, 2025
      If your Salamander Pumps Water Pump starts with all outlets closed, check the system for leaks. Also ensure all outlets are fully closed or capped, meaning there should be no dead legs in the pipework.
  • D
    Diane ScottAug 30, 2025
    Why is my Salamander Pumps CT Force leaking?
    • C
      carlos98Aug 30, 2025
      If your Salamander Pumps Water Pump is leaking, verify that the pump hasn't been exposed to mains water pressure; if it has, fit a break cistern or remove it from the mains supply. Also, check that the pump has not come into contact with any chemical substances, such as solder flux, which could cause chemical damage. Finally, make sure effective temperature control is in place with a cylinder stat or HWS/TMV valve to prevent excessive temperature exposure.
  • M
    Mason AdkinsSep 4, 2025
    Why Salamander Pumps CT Force above hot cylinder becomes noisy or has low pressure?
    • B
      bdanielsSep 4, 2025
      If pumps above a hot cylinder become noisy or experience low pressure during use, aeration or water starvation may be the cause. An essex flange might be needed for the hot connection to the cylinder. Also, ensure the pump is a minimum of 600mm below the cold water tank.