13
Русский
Český
Polski
English
Short description of some selected functions
(all functions are described in the full version of the SQ610RF manual):
1. DISPLAY TEMP RESOLUTION: This function determines the resolution of the displayed temperature -
User can temperature set by steps (every 0,5*C or 0,1*C).
2.
CONTROL ALGORITHM: This function denes how to control the room temperature. Available options
are: ITLC for Underoor Heating / Radiators / Electrical Heating (that’s advanced algorithm for precise
maintenance of room temperature), hysteresis +/-0.5°C or +/-0.25°C, THB Actuator (option recommended
for systems with THB auto balancing actuators).
3.
S1/S2 INPUT: A oor sensor, an external temperature sensor or an occupancy sensor can be connected
to the S1/S2 input of SQ610RF. Additionally, by connecting a NO type of ON/OFF voltage-free contact, you
can use this input as a OneTouch rules trigger (programmed in the Salus Smart Home app) or as a Heat/
Cool changeover.
4.
VALVE PROTECTION: This function activates all actuators once a week for 5 minutes (in summer, this
function helps to prevent the actuators stuck).
5.
MIN TURN OFF TIME: Minimum switch-o time (thermostat will not send the signal for heating/
cooling more often than specied in this parameter).
6. OPTIMISATION FEATURE: Optimum Start and Optimum Stop functions are energy saving feature that
makes thermostat most cost eective (in combination with ITLC control algorithm).
8.
DEVICE INFORMATION: In this menu user can check: Software Version, Battery Level, RF range value,
Paired devices or also user can activate Identication mode.
9. FACTORY RESET:
Here you can RESET your device to factory settings. After successfull reset
device will be removed from ZigBee network and you will need to add / pair your device again.
7. COMFORT WARM FLOOR: This function helps to keep the oor warm, even if the room is warm enough
and there is no need to turn on the heating. User can select 3 levels of warm oor feature. Please note it is
not an economy feature, as your heating system may be ON even if there is no heating demand from the
room thermostat. It is COMFORT feature which keeps your oor warm all the time.