EasyManua.ls Logo

Samson 3251-E - Page 88

Samson 3251-E
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-2 EB 8052-E EN
Decommissioning
Risk of personal injury due to exhaust air
being vented.
While the valve is operating, air is vented
from the actuator, for example, during
closed-loop operation or when the valve
opens or closes.
Î Wear eye protection when working in
close proximity to the control valve.
Risk of personal injury due to residual
process medium in the valve.
While working on the valve, residual me-
dium can ow out of the valve and, depend-
ing on its properties, cause personal injury,
e.g. (chemical) burns.
Î Wear protective clothing, safety gloves,
respiratory protection and eye protec-
tion.
To decommission the control valve for service
work or to remove it from the pipeline, pro-
ceed as follows:
1. Close the shut-off valves upstream and
downstream of the control valve to stop
the process medium from owing
through the valve.
2. Completely drain the pipelines and
valve.
3. Disconnect and lock the pneumatic air
supply to depressurize the actuator.
4. Release any stored energy.
5. If necessary, allow the pipeline and valve
components to cool down or warm up to
the ambient temperature.
WARNING
!
WARNING
!
WARNING
!
WARNING
!

Table of Contents