Translation of original instructions
EB 8015 EN
Edition April 2024
Type3241 Valve · DIN version
In combination with an actuator,
e.g. a Type3271 or Type3277 Pneumatic Actuator
Type3241 Valve with Type3271 Actuator (left) and Type3277 Actuator (right)

Table of Contents

Questions and Answers

  • S
    Sean RothAug 12, 2025
    What to do if increased flow through closed Samson Control Unit valve (seat leakage)?
    • K
      Kristen HillAug 12, 2025
      If you observe increased flow through a closed Samson Control Unit valve, it could be due to dirt or foreign particles lodged between the seat and plug. Try shutting off the pipeline section and flushing the valve to remove any debris. Alternatively, the valve trim, especially with a soft seat, might be worn. In this case, you would need to replace the seat and plug.
  • P
    peggy51Aug 19, 2025
    Why does the Samson Control Unit valve leak to the atmosphere (fugitive emissions)?
    • P
      pwilliamsAug 19, 2025
      A Samson Control Unit valve may leak to the atmosphere due to several reasons. It could be caused by defective packing, or if it's a version with adjustable packing, the packing might not be tightened correctly. Another possibility is loose flanged joints or worn-out body gaskets. Check the flanged joints. If the issue persists, replace the gaskets at the flanged joints.
  • Q
    qyoungAug 27, 2025
    What to do if actuator and plug stem does not move on demand in Samson Control Unit?
    • H
      Harold GrahamAug 27, 2025
      If the actuator and plug stem in your Samson Control Unit do not move on demand, first check if the actuator is blocked and remove the blockage. You can put the control valve out of operation. Also, verify the signal pressure and check the signal pressure line for any leakage. If the diaphragm in the actuator is defective, consult the actuator documentation.
  • T
    Tracey BrownSep 4, 2025
    Why actuator and plug stem does not stroke through the full range in Samson Control Unit?
    • J
      Jeremy GarciaSep 4, 2025
      If the actuator and plug stem in your Samson Control Unit do not stroke through the full range, this could be due to several reasons. Check the signal pressure and inspect the signal pressure line for leaks. Also, the travel stop might be active. Furthermore, incorrect settings of valve accessories can cause this issue, so check the settings of the valve accessories.