Samson S500 Specifications

General IconGeneral
Channels2
S/N Ratio>100dB
Input Impedance20k Ohms balanced, 10k Ohms unbalanced
CoolingConvection
Connectors (Inputs)XLR, 1/4" TRS
Connectors (Outputs)Binding Post, Speakon
Weight8kg
TypeStereo
Dimensions19" x 3.5" x 13.25"

Summary

S500 Features

Guided Tour - Front Panel

Protection LED

Indicates protection circuitry status, mutes speakers, and prevents thumps.

Guided Tour - Rear Panel

Bridged / Stereo / Parallel Switch

Selects amplifier mode: Stereo, Parallel (dual mono), or Bridged (mono).

Setting Up and Using Your S500

The S500 Protection Circuitry

Overheating

Causes protection activation due to high temperature; requires ventilation.

Severe Overcurrent Conditions

Triggered by input signal above 20% THD, causing protection activation.

Shorted Speaker Cables

Faulty wiring causing shorts between hot and ground signals.

Bridged and Parallel Modes

Bridged Mode

Combines both channels for 500W output into an 8-ohm speaker load.

Parallel Mode

Routes Channel 1 signal to both amps for dual mono output at 250W per channel.