15
English
Installation Procedure
Direction of the pipe when brazing
Brazing the pipe should be done with the pipe angled
downward or horizontally.
Avoid brazing with the pipe angled upward.
Cutting the pipes
Make sure that you prepared the required tools.
Pipe cutter, reamer, flaring tool and pipe holder, etc.
If you want to shorten the pipe, cut it using a pipe
cutter ensuring that the cut edge remains at 90° with
the side of the pipe.
There are some examples of correctly and
incorrectly cut edges below.
Oblique Rough Burr
Pipe
Pipe cutter
To prevent a gas leak, remove all burrs at the cut edge
of the pipe using a reamer.
Step 7 Installing oil traps
Check the following list and install an oil trap.
Install an oil trap whenever the indoor unit is installed at a
higher elevation than the outdoor unit.
Based on cooling operation, install it on the gas side
pipe only.
Install an oil trap every 32.8 ft (10 m).
Radius of curvature (R) on the oil trap are as follows;
[inch(mm)]
Pipe
diameter(D)
עߦࢥߩ
(15.88)
עߤࢥߥ
(19.05)
עߨࢥߩ
(22.23)
עߢࣗߢࢥߩ
(28.58)
Radius of
curvatur(R)
1.26 (32)
and over
1.50 (32)
and over
1.61 (41)
and over
2.24 (57)
and over
H
R
Indoor Unit
Outdoor Unit
Oil trap (Install it at
every 32.8 ft (10 m))