Installation Procedure
Connecting wire conduits
When connecting cables between the indoor unit and the
outdoor unit, use conduits to protect the cables.
1 Drill holes on the conduit plate in accordance with
their use and quantity.
Use a nipper to remove conduit holes from the
lower part of the cabinet.
(Do not remove it by hammering.)
Conduit Holes
2 Insert the cables through the conduits, and then fix the
conduits to the conduit plate with the lock nuts.
3 Apply silicone to the end of the hose to prevent rain
from entering the hose.
Silicone
Conduit inserted into the outdoor unit
4 Connect the cables to the outdoor units.
Refer to the next page for connection details.
5 Attach the conduit plate to the product.
Air conditioning system examples
When using earth leakage circuit breaker (ELCB) for a
single phase
1
Communication cable
Indoor Unit
(field supply)
Main power
cable
ELCB
AHU Control Unit
Thermostat
(field supply)
Outdoor Unit
Earthing
࢘Ɵ˵ʪɇΧΧʪɇθɇʀʪͱ˙ϩ˵ʪЇϩɇцɵʪʒ˙˙ʪθʪϩ˙θͱϩ˵ʪ
picture depending on the model.
CAUTION
ELCB must be installed since this product is equipped
with a base heater.
ki]_TXYW][hTWWptjhjG|GvhhluUGGG` YWYYTXWTZXGGG㝘㤸GXWa[_a\^