36 _ Troubleshooting
Error Type
Drum
Fully
automatic
Causes Remarks
Error
mode
Old
error
mode
For USA
Switch Error
(Main Relay
Error)
bE1 12E
E2 -
- ThePowerbuttonispressedcontinually(formore
than12seconds).
- Theswitchispressedunevenlybecauseofa
deformationofthecontrolpanel.
- Thiserrormayoccurwhenthescrewsthathold
thesubPBAinplacearetightenedtoomuch.
bE2 14E
- AbuttonotherthanthePowerbuttonis
continuallypressed(formorethan30seconds).
- Deformationofaninternalplasticinjectionpart
- AscrewforassemblingthesubPBAistightened
toomuch.
bE3 18E Sr -
- ThemainrelayofthePBAisshort-circuited.
- Themainrelayterminalisconnectedincorrectly.
(Theterminalisbentandcontactcannotbe
made.)
Whenthe
PBA motor
relaydoesnot
operate
Cooling Error CE
CE
cE
- -
- Thisoccurswhenthetemperatureofthewashing
machineismorethan55˚Candnodrainingis
performed.
(Reason:Ifhotwatercomesintocontactwithskin,it
maycauseburns.)
- Thisoccurswhenthewatertemperature,fora
speciccourse,exceeds55˚C.Inthatcase,the
waterwillbedrainedtotheResetlevel.
- Thisrepresentsathermalsensorerrororany
misuseoftheunit.
Ifthiserror
occurs for
another
reason,it
isduetoa
washingheater
sensorfault.
Replaceit.
Door Error
dE
door
dE
Ed
door
dS
(Before
operation)
dE
- Aswitchcontacterrorbecauseofadeformation
ofthedoorhook
- Whenthedoorispulledbyforce
Whenthedoor
isnotopened
afterthedoor
open operation
dL
(During
operation)
- ThisoccursintheBoilwashbecausethedooris
pushedduetoapressuredifferencefrominternal
temperaturechanges
Whenthedoor
isnotlocked
afterthedoor
closeoperation
dE1 dE1
LO
(Unlock
Fail)
-
- Thedoorlockswitchterminalisconnected
incorrectly.
- Thedoorlockswitchterminalisbroken.
- Thisoccursintermittentlybecauseofanelectric
wireleakage
- MainPCBfault
FL
(LockFail)
dE2 dE2 - -
- ThisoccursifthePowerswitchisturnedon/off
continuallyandtoomuchheatisgenerated(This
errorisdifculttobereproduced.)
Fan Error FE
F
FE
- -
- Thestartcondenserterminalcomesoutofplace
wheninsertingthetopcover.
- Thefanmotorhasawiredisconnectedorthebelt
isoutofplace.Therefore,thefandoesnotstart.
- Thecoolingwingsarerestrainedorstainshave
developedonthebearings.Therefore,thefan
doesnotstart.
- Startcondenserfault
→Inthiscase,youcannotdetectitwithatester.
Alwaysreplacethestartcondenser