Troubleshooting _ 39
4-2. CORRECTIVE ACTIONS FOR EACH ERROR CODE
► Thesearecommontroubleshootingproceduresforeachdrum-typewashererrormode.Fordetailedinformation,refertothegeneralrepairscripts.
Error Type Error Mode Causes Corrective Actions Description of Photo
WaterLevel
Sensor
1E
• Waterlevelsensorfault
• Incorrectconnectionsofthewater
levelsensorterminal
• Thehosepartforthewaterlevel
sensorisfolded.
• MainPCBfault
• Checkthewaterlevelsensorterminal
connectionsandcontacts.
• Anerroroccursifanincorrectwaterlevel
sensorisused.Makesuretocheckthe
materialcode.(Abnormaloperation)
• Ifthewaterlevelsensorisfaulty,replaceit.
• Iftheerrorpersistsdespitetakingtheaction
above,replacethePBA.
Checkthewaterlevelsensor
frequency.
- Checkitafterthewaterlevel
sensorandtheconnector
areconnected.
- Frequency:Approx.26.4
KHzwithnoload
WashingMotor
ErrorandHall
Sensor Error
3E
3E1
3E2
3E3
3E4
• Washingmotorfault
• Washingmotorhallsensorfault
• Incorrectconnectionsofthe
washingmotor/hallsensor
connector
• Washingmotorrotorandstator
fault
• MainPCBfault
• Checkthemotorconnectorterminal
connectionsandcontacts.
• 3E1isdisplayedbecauseoverloadingoccurs
duetotoomuchlaundry.
• Ifthehallsensorterminalisfaulty,replacethe
hallsensor.
• Checkwhetherthestatorofthemotorcoveris
damaged.
• Checkforcoildisconnectionsduetoforeign
material.
• IfthePBAcontrolcircuitisfaulty,replacethe
PBA.
► DDMOTOR
Checktheresistanceonthe
mainPCBmotor.(Betweenpins
1and3,and1and4ofthefour
(4)pins)
- Resistance:Approx.2to4
MΩ
- Checkthevoltagewhenthe
powerison.
► UNIVERSALMOTOR
ChecktheResistanceofNos.1
and4ofthewirepinontheside
oftheTACHOSENSOR.
- Resistance:Approximately
40to45Ω(Normal)
► THREEPHASEMOTOR
MeasuretheResistanceofNos.
2and3ofthewirepinonthe
sideoftheHALLSENSOR.
- Therevolutionofthedrum
needstobereproduced.
(Turnthedrumbyhand.)
- Resistance:Approximately3
to12V(Voltagesmaydiffer
dependingonthespeedof
therevolutions.)