ENGLISH-39
02 INSTALLING THE PRODUCT
Classication Example Remarks
Maximum
allowable
pipe length
Outdoor unit ~
Indoor unit
Actual pipe
length
(Equivalent
length)
170 m and
below (190
m and
below)
Installing only with
Y-joint
a+b+c+d+e+f+g+p ≤
170 (190) m
Equivalent length
• Y-joint: 0.5 m
• Distribution
header: 1 m
Installing with
Y-joint and
distribution header
a+b+h ≤ 170 (190) m,
a+i+k ≤ 170 (190) m
Installing only with
distribution header
a+i ≤ 170 (190) m
Total length
of pipe (m)
500 m or
less
Installing only with
Y-joint
a+b+c+d+e+f+g+p+h+
i+j+k+l+m+n ≤ 500 m
Installing with
Y-joint and
distribution header
a+b+c+d+e+f+g+h+
i+j+k ≤ 500 m
Installing only with
distribution header
a+b+c+d+e+f+g+h+i
≤ 500 m
Outdoor unit~
Outdoor unit
(Module
installation)
Pipe length 10 m or less r ≤ 10 m, s ≤ 10 m, t ≤ 10 m
Equivalent
length
13 m or less r ≤ 13 m, s ≤ 13 m, t ≤ 13 m
Height
dierence
1.5 m or less H5 ≤ 1.5 m
H5
Maximum
allowable
height
dierence
Outdoor unit ~
Indoor unit
50/40 m
Note 2)
H1 ≤ 50/40 m
Indoor unit ~
Indoor unit
50 m or less H2 ≤ 50 m
Maximum
allowable
length after
branch joint
First branch
joint ~ Farthest
Indoor unit
Pipe length
45 m or less b+c+d+e+f+g+p ≤ 45 m, i ≤ 45 m
45 m ~ 90m
note 1)
Required conditions must be satised
EEV kit Model Remarks
EEV kit ~
Indoor unit
Actual pipe
length
2 m
MEV-E24SA
1 indooor
Apply to products without EEV
(Wall mount & ceiling)
MEV-E32SA
20 m or less
MXD-E24K132A
2 indooorMXD-E24K200A
MXD-E32K200A
MXD-E24K232A
3 indooor
MXD-E24K300A
MXD-E32K224A
MXD-E32K300A
Please refer to the EEV Kit manual.