Connecting the Cables to the Outdoor Unit
Two electric cables must be connected to the outdoor unit:
The assembly cable connecting the indoor unit to the outdoor unit.
The power cable connecting the auxiliary circuit breaker to the
outdoor unit.
1 Remove the terminal board cover on the side of the outdoor unit.
2 Connect the assembly cable to terminals 1, 2, 3, 5 and connect the power
cable to terminals N to L.
Each wire is labelled with the corresponding terminal number.
3 Connect the earth wires to the earth terminals.
Refer to the page opposite for further details on how to check
that earthing is correct.
4 Replace the terminal board cover, carefully tightening the screw.
5 Connect the power cable to the auxiliary circuit breaker.
1 2 3 4 5
1 2 3 4 5
1 532
1 E
LN
2 35
E
E
NEL
Indoor unit
Outdoor unit
Circuit Breaker
(Main Power)
Earth
terminal
Earth
terminal
E-34