14-2Samsung Electronics
14-2 Refrigerant Pressure during the Charging
Outdoor Unit Temperature Low Pressure kg/cm
2
(PSIC)
Less than 20˚C 4.5 ~ 4.7(64~67)
Less than 24˚C 4.7 ~ 4.8(67~68)
Less than 28˚C 4.8 ~ 4.9(68~70)
Less than 32˚C 4.9 ~ 5.0(70~71)
Less than 36˚C 5.0 ~ 5.1(71~73)
Less than 40˚C 5.1 ~ 5.2 (73~74)
Less than 44˚C 5.2 ~ 5.3 (74~75)
14-3 Pressure & Capacity mark
W cal/s kcal/h Btu/h HP kg
.
m/s ib
.
m/s
1
4.1868
1.163
0.29307
745.7
9.8067
1.3558
0.23885
1
0.27778
0.06999
178.11
2.3423
0.32383
0.85985
3.6
1
0.252
641.19
8.4322
1.1658
3.4121
14.286
3.9683
1
2,544.4
33.462
4.6262
0.001341
0.0056146
0.0015596
3.9302x10
-4
1
0.013151
0.0018182
0.10197
0.42693
0.11859
0.029885
76.04
1
0.13826
0.73756
3.088
0.85778
0.21616
550
7.233
1
Power/Heat