28 _ Troubleshooting
4-2. TEST MODE
■ Continuous Run Mode
■ TEST MODE
PowerOnstate
(Normalusermode)
Wrinkle Prevent +
Dry Level 7 SEC
Continuous Run Mode
Continuous Run Mode :
1. PressWrinklePrevent+DryLevelfor7secduringPowerOnState(NormalUserMode).
2. OnceinContinuousRunMode,display“CC”for1secandthenumberofCyclefor1secandtheremainingtimefor1
sec in turns.
3. ThepreviouscyclewillrestartduringContinuousRunModeuntilthemodeisdeactivated.
4 DuringContinuousRunMode,pressWrinklePrevent+DryLevelfor7secondstoreturntonormalusermode.
■ Service Mode
DenitionofServiceMode:
• DryermustbeonbeforeServiceModecanbeentered.
• UponentryintoServiceMode,theSensorBarTouchDatawillbeshown(DefaultServiceMode).
How to Enter :
• ToenterServiceMode,pressWrinklePreventandTempKeysfor3seconds,untilitsendsoutabeepingsound.
• IfpressingWrinklePrevent+TempKeysfor3secondsinServicemode,itwillreturnNormalmode.
• EventhoughenteringServicemode,theoperatingcyclewillnotbeinuenced.
■ Sensor Bar Touch Data Mode
DenitionofSensorBarTouchDataMode:
• Thisactionwillputthedryerintosensorbartouchdatamode.
• DryerwilldisplaySensorBardata.Thismodeisdefaultmodeofenteringservicemode
How to Enter :
• WithPowerOnpressingWrinklePreventandTempKeysfor3seconds.
■ Cycle Count Mode
DenitionofCycleCountMode:
• ThismodeistobringupthetotalnumberofcyclesthatUserhavecarriedout.
How to Enter :
• ToentercyclecountmodepresstheWrinklePreventinServiceMode.
■ Software Version Mode
DenitionofSoftwareVersionMode:
• Itistoretrieveitssoftwareversion.
How to Enter :
• AtServiceMode,pressTempuntilitsendsoutabeepingsound.
ex)Incaseof“U005”,U0meansmajorversion“U0”05meansminorversion“05”.
• IfpressTempkeyInSoftwareVersionMode,itwillreturnServiceMode.
■ Data Display Mode
DenitionofTemperatureDisplayMode:
• DisplayMode0:Temperaturedata(Celsius).
• DisplayMode1:AverageTouchSensordatafor1minute.
• DisplayMode2:AverageTemperature(Celsius)datafor1minute.
How to Enter :
• WithPowerOn,pressAdjustUpKey+AdjsutDownKeyfor7secondsuntilitsendsoutabeepingsound.
• Ifnotpressedanykeysfor5minutes,itwillbesetbackfromDataDisplayMode.
• IfpressingAdjustUpKeyinthismode,DisplayModeIDwillbeincreased.
• IfpressingAdjustDownKeyinthismode,DisplayModeIDwillbedecreased.
Converting°C→°F
Celsius(°C) -30 -10 10 30 50 70
Fahrenheit(°F) -22 14 50 86 122 158
F=9/5C+32