35
ENGLISH
33.6kW 40.0kW
(D)
(E)(C)
(A)
(B)
(3)(2)(1)
61.6kW
Branch joint
f Branch joint between outdoor units (C)
Classication Model name Specication (kW)
Y-joint for outdoor unit (C)
MXJ-TA3419M 135.2kW and below
MXJ-TA4122M Over 135.2 kW
f First branch joint (D)
Make a selection according to outdoor unit capacity.
Classication Outdoor unit capacity (kW)
Model name of the
branch joint
Y-joint (D)
40.0kW and below MXJ-YA2512M
40.1 kW ~ 45.0 kW MXJ-YA2812M
45.1 kW ~ 67.2 kW MXJ-YA2815M
67.3 kW ~ 95.2 kW MXJ-YA3419M
95.3 kW ~ 135.2 kW MXJ-YA4119M
Over 135.2 kW MXJ-YA4422M
f Branch joint (E)
Select a branch joint according to the sum of indoor unit capacity which will be connected after the branch.
However, if the size of the pipe between branch joints (E) is bigger than the size of the pipe connected to the outdoor unit
(D), apply the pipe size (D).
1) Y-joint
Classication Model name Specication (kW)
Y-joint (E)
MXJ-YA1509M 15.0kW and below
MXJ-YA2512M 15.1 kW ~ 40.0 kW
MXJ-YA2812M 40.1 kW ~ 45.0 kW
MXJ-YA2815M 45.1 kW ~ 70.3 kW
MXJ-YA3419M 70.4 kW ~ 98.4 kW
MXJ-YA4119M 98.5 kW ~ 135.2 kW
MXJ-YA4422M Over 135.2kW
2) Distribution header
Classication Model name Specication (kW)
Distribution header (E)
MXJ-HA2512M 45.0kW and below (for 4 rooms)
MXJ-HA3115M 70.3kW and below (for 8 rooms)
MXJ-HA3819M 70.4 kW ~ 135.2 kW