CMS
A. Device Information: Basic information of a CMS object.
Name: Specify the name of CMS.
Location #1 ~ #4: Specify the location where the CMS is installed. According to a whole
system diagram, up to 4-depth location can be specified.
Description: Input the relevant information on the CMS.
B. IP Configuration: Network information of a CMS object.
Address Type: Specify one of network address type.
IP Address: Enter network IP address.
Subnet Mask: Enter subnet mask address.
Gateway: Enter network gateway address.
DNS Server: Enter DNS server address.
C. Device Capabilities: Display maximum number of connectable devices for live monitoring.
D. Advanced Setup – CMS Device Configuration: Open the advanced setting window for CMS.
Device>Add Device: Resister selected devices for monitoring
Connectable Network Cameras/Encoders displays only the list of camera and
encoder which are physically connected to the CMS in your diagram.
CMS Live Channel>CMS Live Channels: Resister selected devices for live monitoring
Connectable Network Cameras/Encoders displays only the list of camera and
encoder which are physically connected to the CMS in your diagram.
You can select specific profile for live monitoring from each device.