9) If PANTRY Sensor has trouble
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN30 and CN76 insert
correctly?
Is Pantry Sensor
normal?
Is the voltage between
MAIN PCB Connector CN30-"9"(Yellow)
and J23 JUMMPER normal?
Is the input voltage of IC01
MICOM Pin #87 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Recheck the wiring connection
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
** Measuring point of resistance value according to Sensor
**
Flex : CN30 ”9” CN76 ”1” measuring resistance value
** 0: Short trouble / Ω∞: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #87,
CN30-"9"(Yellow)and J23 JUMMPER
from PCB typical Ground part are similar.
Check the measure on the voltage of Resistance, R314
due to the SMD MICOM
Checking method of PANTRY Sensor resistance
CN30-"9"(Yellow) CN76-”1” (Gray)
- Compare the temperature table after measurement.
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
Pantry
Connector CN30-"9"(Yellow) to
J23 JUMMPER PCB typical Ground
Checking method of PANTRY Sensor resistance CN30-
"9"(Yellow)
CN76-”1” (Gray)
- Compare the temperature table after measurement.
Measuring voltage of CN30-"9"(Yellow)
J23 JUMMPER are
as below
PCB Typical Ground
J23 JUMMPER
Start
YES
YES
YES

Table of Contents