63
TROUBLESHOOTING
4) If Ambient Sensor has trouble
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN32 inserted
correctly?
Is Ambient Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN32#1(White)
to CN1#3(Black) normal?
Is the input voltage of
IC01 MICOM #59 normal?
Start
NO
YES
YES
YES
YES
Replace the temperature sensor
NO
Recheck the wiring connection
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder
NO
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
** Measuring point of resistance value according to
Sensor **
Ambient : CN32#1 #4 measuring resistance value
** Placed in the right top table of upper hinge.
** 0 : Short trouble / : Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #59,
CN32#1(White) and CN1#3(Black) from
PCB typical Ground part are similar.
Checking method of Ambient Sensor resistance
CN32#1(White) #4(White)
- Compare the temperature table after the
measure
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
Ambient
Connector CN32#1(White) to
CN1#3(Black) PCB typical Ground
Checking method of Ambient Sensor voltage
- Measure the voltage of Sensor Check Point #7(IC01 MICOM #59)
on PCB or CN32#1(White) CN1#3(Black)
- Compare the temperature table after the measure
Measuring voltage of CN32#1(White) CN1#3(Black) are below
typical PCB Ground
CN1#3(Black)