EasyManua.ls Logo

Samsung RF267AABP - Page 66

Samsung RF267AABP
137 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64
TROUBLESHOOTING
5) If F Sensor has trouble
Bad contact of connector/ insert correctly
Are MAIN PCB
Connector CN30 to CN75
inserted correctly?
Is F Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN30#3(Red) to
CN1#3(Black) normal?
Is the input voltage of
IC01 MICOM #52 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Recheck the wiring connection
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder
NO
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
** Measuring point of resistance value according to
Sensor **
F : CN30#3 CN75#1 measuring resistance value
** 0 : Short trouble / : Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #52,
CN30#3(Red) and CN1#3(Black) from
PCB typical Ground part are similar.
Checking method of F Sensor resistance
CN30#3(Red) CN75#1(Gray)
- Compare the temperature table after the measure
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
F
Connector CN30#3(Red) to
CN1#3(Black) PCB typical Ground
Checking method of F Sensor voltage
- Measure the voltage of Sensor Check Point #1(IC01 MICOM #52)
on PCB or CN30#3(Red) CN1#3(Black)
- Compare the temperature table after the measure
Measuring voltage of CN30#3(Red) CN1#3(Black) are below.
typical PCB Ground
CN1#3(Black)
2¢(-19¡) is recommended 38¢(3¡) is recommended
Start
YES
YES
YES

Table of Contents