EasyManua.ls Logo

Samsung SR-686EV - Load Status Display

Samsung SR-686EV
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics 15
7-11 Load status display
1) Press power F/R key for five seconds then press temperature control key in the refrigerator after
temperature display lamps on and off three times.
2) This mode shows which load is being sourced signal from MICOM currently. This doesn’ t mean
the load is operating but just show MICOM signal output. The Compressor may not operate due
to the open wire or relay missing though the display shows the Compressor operating.
3) Load status display return to normal mode after sixty seconds.
4) Follows are load status and related display.
No
1
2
3
4
5
6
7
8
9
10
11
12
Display LED
Freezer “Low”
Freezer “Low · Mid”
Freezer “Mid”
Freezer “Mid · High”
Freezer “High”
Refrigerator
“Low · Mid”
Refrigerator “Mid”
Refrigerator
“Mid · High”
Refrigerator “High”
Quick Freezing
Quick Refrigeration
High humidity
refrigeration
Display
Relevant LED ON during
Compressor operation
Relevant LED ON during F-FAN
operation
Relevant LED ON during freezer
defrost heater on
Relevant LED ON during freezer
bulb ON
Relevant LED ON during
Compressor Cooling Fan oeration
Relevant LED ON during F-FAN
operation
Relevant LED ON during
refrigerator defrost
Relevant LED ON during
refrigerator bulb ON
Relevant LED ON during
refrigerator brade rotation
Relevant LED ON with initial
power input
Relevant LED ON when ROOM
temperature is over 35˚C
Relevant LED On when ROOM
temperature is below 20˚C
Remark
Item
COMP
F-FAN
Freezer defrost Heater
Freezer bulb
COMP. Cooling Fan
R-FAN
Refrigerator defrost
Heater
Refrigerator bulb
GEARED-Motor
Initial Mode
Overload
Low temp.
Refrigerator Subordinate
Mode Display
Freezer Subordinate
(Load Status Display Table)

Table of Contents