EasyManua.ls Logo

Samsung SVR-1680 - Page 33

Samsung SVR-1680
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Install Manual
32
as Relay out, the Output can be operated with digital I/O. Also, if Input is operated, the
emergency recording is started. Then the emergency recording starts to record with the Event
Record value.
Specification
The D-I/O specifications are as follows.
No. of inputs/outputs 12
Output type DC 3V output
Specification
Connection method Connect stripped wire end with 15 pin D_SUB.
Rated
current
DC 3.3 ~ 5V
D-I/O Connection
D-I/O inputs/outputs are connected shown in the following figure. Please refer to the section on
handling wiring for information about connecting and disconnecting.
D-I/O Settings
The 12 D-I/O ports are split with 6 for input and 6 for output. They can be configured under the
Event Setup menu tab.

Other manuals for Samsung SVR-1680

Related product manuals