6-10
-If you plug in the power cord and turn Power S/W on, memorized data is displayed.
If any data is not displayed, check the followings.
Thermistor Check
Check Voltage at Pin #6 and #3 of CN3
Tester Check = DC2.5V
If it reads 5V, check if its connector is engaged properly.
Door Switch Check
Check Voltage at Pin #6 and #4 of CN3
When Door Open = DC5V
When Door Close = DC0V
Water Sensor Check
Check Voltage and Frequency at Pin #6 and #7 of CN3
Reset water level = DC2.5V, 25.8KHz
Check Voltage and Frequency at Pin #6 and #8 of CN3
Reset water level = DC2.5V, 25.8KHz
Sump Sensor Check
Check Voltage at Pin #4 and #2 of CN8
Tester Check = DC0V or 3.75V
Check Voltage at Pin #4 and #3 of CN8
Tester Check = DC0V or 3.75V
Motor Check
Resistance at Pin #1 and #2 of CN9 =11.6
Resistance at Pin #1 and #3 of CN9 =11.6
Resistance at Pin #2 and #3 of CN9 =11.6
Door Lock Check
Check Voltage at Pin #1 of CN5 and Pin #7 of CN10
When Door Lock = AC120V
Check Voltage at Pin #1 of CN5 and Pin #2 of CN7
When Door Lock = AC120V
Door Unlock Check
Check Voltage at Pin #1 of CN5 and Pin #8 of CN10
When Door Unlock = AC120V
Drain Motor Check
Check Voltage at Pin #1 of CN5 and Pin #6 of CN10
When Drain Pump operates = AC120V
Water Valve Check
Check Voltage at Pin #1 of CN5 and Pin #1,2,3,4 of CN10
When each Valve operates = AC120V
AC Power Check
Check Voltage at Pin #1 and #3 of CN5
Check Voltage at Pin #1 of CN5 and Pin #1 of CN6
Tester Check = AC120V
Heater Relay Check
Check Voltage at Pin #1 of CN5 and Pin #2 of RY9
When Heater Relay operates = AC120V
6-2. PROBLEM CHECKING AND METHOD OF PCB

Other manuals for Samsung WF337AAG