EasyManua.ls Logo

Samsung WF337AAG - Ag Pba Connector Terminal Description & Layout (the Principle Part)

Samsung WF337AAG
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-5
CN1
1. Connects to Main PBA CN7 (AC2)
2. NC
3. Connects to EMI Filter (AC1)
CN2
1. Connects to AG PBA (Ground)
2. Connects to AG PBA (I_H)
3. Connects to AG PBA (PWM)
4. Connects to AG PBA (Signal A)
5. Connects to AG PBA (Signal B)
6. NC
7. NC
8. Connects to AG PBA (Ag_A)
9. Connects to AG PBA (Ag_B)
Item Part Number Description
1 LVT1 Chopping the DC Link
2 R37
Dummy Load (For Making the Operation
Voltage)
3 L1 Help for the EMI, EMC
4 IC3 Making a stable DC
5 PC Isolation for the water
6 IC2 Comparator
7 TR1~4 Change the water ow
10-5. AG PBA CONNECTOR TERMINAL DESCRIPTION & LAYOUT (THE PRINCIPLE PART)