10-2
CN3
1. NC
2. NC
3. Connects to Water Temperature Sensor
4. Connects to Door Lock switch
(Door Open/Close Sensor)
5. Connects to Ground
6. Connects to Ground
7. Connects to Water Level Sensor (Signal A)
8. Connects to Door Lock Switch (Signal B)
9. Connects to Ground
CN2
1. Connects to Sub PBA (Seq0)
2. Connects to Sub PBA (Rotary Switch A)
3. Connects to Sub PBA (Rotary Switch B)
4. Connects to Sub PBA (Key2)
5. Connects to Sub PBA (Key3)
6~13. Connects to Sub PBA
(Digit Signal 0~7 / In Regular Sequence)
CN1
1. Connects to Sub PBA (Ground)
2. Connects to Sub PBA (Vcc)
3. Connects to Sub PBA (Key 1)
4~13. Connects to Sub PBA
(Seg1~9,13/In Regular Sequence )
CN4
1. Connects to AG PBA (I_H)
2. Connects to AG PBA (PWM)
3. Connects to AG PBA (AG A)
4. Connects to AG PBA (AG B)
5. Connects to AG PBA (Ground)
CN8
1. Connects to Hall Sensor (Vcc)
2. Connects to Hall Sensor (Signal B)
3. Connects to Hall Sensor (Signal A)
4. Connects to Hall Sensor (Ground)
CN10
1. Connects to Main Valve
2. Connects to Hot Valve
3. Connects to Pre Valve
4. Connects to Bleach Valve
5. NC
6. Connects to Drain Pump
7. Connects to Door Lock Switch
(For the Close)
8. Connects to Door Lock Switch
(For the Open)
CN9
1. Connects to Motor (U Phase)
2. Connects to Motor (V Phase)
3. Connects to Motor (W Phase)
Relay 9
1. Connects to Washing Heater
2. Connects to EMI Filter
(Remove the Noise/AC2)
CN7
1. Connects to AG Kit
(Supply for the power)
2. Connects to
Door Lock Switch
(For the Safety)
CN5
1. Connects to EMI Filter
(Remove the Noise/AC1)
2. NC
3. Connects to Relay 9