9.9 Brightness/Color Calibration
Online Calibration
Online calibration is that NovaCLB (calibration software) connect NovaLCT through
network for calibration of LED displays.
It supports single-screen mode and combined-screen mode.
l Current Serial Port
This is the serial port through which the LED display to be calibrated is connected to the
computer.
l Current Screen
The LED displays connected to the computer will be list in this panel. Select the LED
display to be calibrated from the list.
l Local IP
This is the IP address that NovaLCT listens to. It is actually an IP of the computer on
which NovaLCT is running.
l Port
This is the port that NovaLCT listens to.
l Reconnect
Click this button to terminate the current listening process and start a new listen process
using the settings of Local IP and Port.
l Communication Log
Records of the communication between NovaCLB and NovaLCT are listed is this panel.
l Enable Calibration
This option is to enable or disable LED display calibration using calibration coefficients.
l Save button in the Enable/Disable Calibration panel
Click this button to save the calibration switch status (enable or disable) to the hardware.
l Save button in the communication log panel
Click this button to save the communication log to a text file.