EasyManua.ls Logo

Samwon Tech TEMI1500 - Program Pattern Setting

Default Icon
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52
[Fig. 7-2] Pattern editing screen
2
3
4
5
6
1
7
8
9
10
11
7-1. Program pattern setting
●Itisascreentosetthesegmentdependingonthepatternnumber.
●Referto[7-4Timesignaloperation]fortimesignalsetting.
●Pleaserefertothe[7-5Standbyoperation]tofindthingsaboutthestandbyoperation.
Inputthepatternnumberforsegmentsetting
Settingthestartconditionforprogramoperation.
NOWPV:ItstartsfromthepresentPVforpresentsetvalueSPin
startingofprogramoperationandprogressedtothesettime(TM1)
forcurrentlysetvalue(SP1)insegment(SEG1)
TEMPSSP:Incaseofstartingtheprogramoperation,thepresent
setvalue(SP)isstartedfromtemperatureSSPandprogressesto
thesettime(TM1)forcurrentlysetvalue1(SP1)insegment1(SEG1).
HUMISSP :ItstartsfromthesetSSPforpresentsetvalue(SP)in
startingofprogramoperationandprogressedtothesettime(TM1)
forcurrentlysetvalue1(SP1)insegment1(SEG1).
Itsetsthetemperaturesetvalueofsegmenttobeoperated.
Itsetsthehumiditysetvalueofsegmenttobeoperated.
Settingthetimeofsegmenttobeoperated.
Itsetsthetimesignalofthesegmenttobeoperated.
4timesignalscanbesetforeachsegmentandeachtimesignal
issetbyselectionfrom18typesoftimesignal.
Referto[7-4Timesignaloperation]

Related product manuals