20. Loc
uLoc
20.0
0.900 1.100
SAVE
12.5
0.900 1.100
SAVE
11.3
11.
for 2 sec.
The PAT lamp and
the SAVE indication
blink 2 times.
※The vibration quantity
has been saved.
for 2 sec.
The PAT lamp and
the SAVE indication
blink 2 times.
※ If the Func key is pressed without
the SAVE operation, the changes
are not saved but cancelled.
Press the Func
key 3 times.
The saved vibration quantity is assumed
as
the reference (1.0 times).
speed is adjusted by directly
voltage% is that as of saving, and
in proportion to the magnification.
function is valid only when the
made to the parameter No. 0u=1.
※ Be sure to perform the SAVE
operation when the feeder is in
⑥-C Fine-adjustment of the vibration quantity
※The decimal point is displayed.
※ Adjust the magnification while confirming
the operation condition.
Perform this operation slowly and carefully.
※ Adjust the magnification while
confirming the operation condition.
※ This shows the status in which the voltage%
becomes 12.5% when the vibration quantity is
changed by 0.900 times as an example.
However, even if the vibration quantity is
decreased, the voltage% does not always lower.
So is the case when the vibration quantity is
increased.
※If there is no key operation for
2 min, the Loc status is resumed.
Blinking
Blinking