27 / 32
2) Parameter list
Each time the Vol▲ key is pressed, the parameter display switches in the descending order of the following
table. Each time the Vol▼ key is pressed, the parameter display switches in the ascending order.
Display
according to
the operation
mode
in2 Input OFF delay timer
OUT4 Output stop delay
timer
in2 Input parts shortage
detection
oF: The remote unit is invalid.
on: The remote unit is valid.
Setting of the speed of output
response to vibration change
when the constant-amplitude
control is in process
1 (slow) ⇔ 27 (fast)
hi: Operation
with the contact
“Close”
Lo: Operation
with the contact
“Open”
Setting of OUT2 Output
function
FBU amplification
setting
Set the amplification rate of the
feedback sensor value.
0 (no amplification) ⇔ 3 (large
amplification)
Limit the maximum value of
the output voltage.
Backup display pattern No.
Output voltage backup display
io01: With overflow stop
io02: Without overflow stop
Amplitude control
setting
0: Constant voltage
1: Constant-amplitude
Change during operation: 〇 … Enabled, ×… Disabled , … Not applicable
Display according to mode: 〇 … Enabled, -… Disabled