5
INSTALLATION GUIDE
Ensure that the site where the SRMax will be located
can be supplied with the necessary power requirements
(120-240V @ 50-60Hz). To nd out the power consump-
tion of the SRMax refer to the marking label on your unit.
Make sure that there is adequate clearance for service.
Any plastic components in direct line-of-sight of the
UV lamp should be shielded from direct UV exposure
with aluminum foil or removed when possible.
e Sanuvox wire-set is Teon coated which makes it
resistant to UV exposure.
e SRMax reecting chamber has to be installed parallel
to the airow with the turbulator upstream to slow
down the air as it moves in front of the UV lamp.
e suggested operating temperature range is 10 to
50°C (50 to 120°F). Operating the SRMax outside this
range will result in decreased performance. For optimal
performance, air temperature moving through the reaction
chamber should be in the range of 15 to 20°C (60 to 70°F).
e SRMax is not weatherproof. Do not install outdoors
WARNING
Follow all the Safety Instructions outlined in this document and respect all local and national codes applicable.