8
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2-2-2. Outdoor Unit
(1) Outdoor unit C0951 / CL0951
Control PCB
Part No. — / POW-CL0951
Controls
Control Circuit Fuse AC 250V – 3A
Compressor
Type Rotary (Hermetic)
Compressor model C-1R75H2R
Nominal output W 750
Compressor oil … Amount cc SUNISO 4GSD-T … 350
Coil resistance (ambient temp. 68°F (20°C)) C – R: 0.841
C – S: 2.831
Safety devices Type External (OLR)
Overload relay MRA99111-9200
Run capacitor µF 40
VAC 400
Crank case heater — / 115V, 20W
Fan & Fan Motor C0951 CL0951
Type Propeller
Q’ty … Dia. and length inch. (mm) 1 … 16-17/32 (ø 420) 1 … 16-17/32 (ø 420)
Fan motor model … Q’ty UE6-21BA1P … 1 UE6T-21J1P … 1
No. of poles … rpm (115V, High) 6 … 630 6 … 630
Nominal output W 20 20
Coil resistance (ambient temp. 68°F (20°C)) BLU BRN: 45.3 BLU BRN: 45.3
BLU PNK: 50.5 BLU PNK: 50.5
Run capacitor µF 7 7
VAC 220 220
Heat Exchanger Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch inch (mm) 1/16 (1.4)
Face area ft
2
(m
2
) 3.27 (0.304)
External Finish Acrylic baked-on enamel finish