EasyManuals Logo

Sanyo C0951 User Manual

Sanyo C0951
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
11
2-3. Other Component Specifications
2-3-1. Indoor Unit
(1) Indoor unit KS0951
Transformer ATR-T4
Rating Primary AC 115V, 60Hz
Secondary 19V, 0.5A
Thermistor (Coil sensor) DTN-TKS131B
Resistance k 32°F (0°C) 15 ± 2%
Thermistor (Room sensor) DTN-TKS134B
Resistance k 77°F (25°C) 5 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance k 32°F (0°C) 15 ± 2%
Thermistor (Room sensor) DTN-TKS134B
Resistance k 77°F (25°C) 5 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance k 32°F (0°C) 15 ± 2%
Thermistor (Room sensor) DTN-TKS142B
Resistance k 77°F (25°C) 5 ± 3%
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
(2) Indoor unit KS1251
Transformer ATR-T4
Rating Primary AC 115V, 60Hz
Secondary 19V, 0.5A
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
(3) Indoor unit KS1852
Transformer ATR-T5
Rating Primary AC 230V, 60Hz
Secondary 19V, 0.5A
DATA SUBJECT TO CHANGE WITHOUT NOTICE.