26
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Cooling
(1) Indoor unit KS0951
Outdoor unit C0951 / CL0951
115V single-phase 60Hz
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 115V single-phase 60Hz
Rating conditions Running amp. A 0.40 0.655 7.7 8.8
Power input kW 0.034 0.075 0.79 0.90
Full load conditions Running amp. A 0.4 0.655 9.4 10.5
Power input kW 0.034 0.075 1.04 1.15
Rating conditions: Indoor air temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor air temperature 95°F (35°C) D.B.
Full load conditions: Indoor air temperature 95°F (35°C) D.B. / 70°F (21.2°C) W.B.
Outdoor air temperature 115°F (46.1°C) D.B.
(2) Indoor unit KS1251
Outdoor unit C1251 / CL1251
115V single-phase 60Hz
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 115V single-phase 60Hz
Rating conditions Running amp. A 0.40 0.704 9.8 10.9
Power input kW 0.034 0.081 1.09 1.20
Full load conditions Running amp. A 0.4 0.704 12.2 13.3
Power input kW 0.034 0.081 1.41 1.52
Rating conditions: Indoor air temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor air temperature 95°F (35°C) D.B.
Full load conditions: Indoor air temperature 95°F (35°C) D.B. / 70°F (21.2°C) W.B.
Outdoor air temperature 115°F (46.1°C) D.B.
(3) Indoor unit KS1852
Outdoor unit C1852 / CL1852
230 / 280V single-phase 60Hz
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V single-phase 60Hz
Rating conditions Running amp. A 0.25 / 0.23 0.498 / 0.465 7.1 / 7.7 7.8 / 8.4
Power input kW 0.047 / 0.045 0.113 / 0.095 1.56 / 1.53 1.72 / 1.67
Full load conditions Running amp. A 0.25 / 0.23 0.498 / 0.465 8.6 / 9.5 9.3 / 10.2
Power input kW 0.047 / 0.040 0.113 / 0.095 1.93 / 1.96 2.09 / 2.10
Rating conditions: Indoor air temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor air temperature 95°F (35°C) D.B.
Full load conditions: Indoor air temperature 95°F (35°C) D.B. / 70°F (21.2°C) W.B.
Outdoor air temperature 115°F (46.1°C) D.B.
000-215 SM (1-56) 7/5/00 2:49 PM Page 26