3
(2) Indoor unit KS1251
Outdoor unit C1251 / CL1251
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are
Cooling: Indoor air temperature 80°F D.B. / 67°F W.B.
Outdoor air temperature 95°F D.B. / 75°F W.B.
Performance Cooling
Capacity kW 3.46
BTU/h 11,800
Air circulation (High) ft
3
/min 330 (9.35)
Moisture removal (High) Pints/h 3.4
Electrical Rating Cooling
Available voltage range V 104 – 126
Running amperes A 10.9
Power input W 1,200
Power factor % 96
SEER BTU/W 10.2
Compressor locked rotor amperes A 60
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON / OFF 12 hours, 1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1 (Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment lb. (kg) 1.76 (0.8)
Refrigerant control Capillary tube
Operation sound Indoor: Hi / Me / Lo dB-A 41 / 38 / 34
Outdoor: Hi dB-A 48
Refrigerant tubing connections Flare
Max allowable tubing length at shipment ft. (m) 25 (7.5)
Refrigerant tubing Narrow tube inch (mm) 1/4 (6.35)
diameter
Wide tube inch (mm) 1/2 (12.7)
Cooling
Voltage Rating 115V
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height inch (mm) 10-5/8 (270) 21-1/4 (540)
Width inch (mm) 31-11/16 (805) 31-1/2 (800)
Depth inch (mm) 6-31/32 (177) 11-13/32 (290)
Package dimensions Height inch (mm) 9-13/16 (249) 23-31/32 (609)
Width inch (mm) 33-21/32 (855) 38-5/8 (981)
Depth inch (mm) 13-5/16 (338) 16-3/16 (411)
Weight Net lb. (kg) 17.6 (8.0) 75.0 (34)
Shipping lb. (kg) 22.0 (10.0) 83.8 (38)
Shipping volume cu.ft (m
3
) 2.51 (0.071) 8.67 (0.246)
000-215 SM (1-56) 7/5/00 2:49 PM Page 3