EasyManua.ls Logo

Sanyo C4272R - Page 156

Sanyo C4272R
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
2
3
4
5
6
IV-10
SM831148
4. Service procedures
HIC +
Between terminals Resistance
HIC +
HIC +
HIC +
HIC
HIC
HIC
HIC
U
V
W
U
V
W
Resistance
200 k or more
300 k or more
300 k or more
300 k or more
200 k or more
200 k or more
200 k or more
No
Yes
Replace outdoor unit
control PCB.
(3) [Alarm E31]
(communications
trouble within unit)
IGBT short-circuit protection
Is E31
displayed even after
the power voltage
is reset?
Normal
HIC-CH4872R
(42 Type)
HIC-CH2672R
(26, 30, 36 Type)

Table of Contents

Related product manuals