1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No. THH3672R
Source 230 - 208 V / 1 phase / 60 Hz
Remote controller (Option) Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y CR - TH2672
Control circuit fuse 250 V, 5 A
Fan (Number ... diameter) in. (mm)
Fan motor
Model
Source
No. of pole ... r.p.m. (230 V, High) rpm 4 ... 1,015
Nominal output W 100
Coil resistance
(Ambient temperature 68 °F)
Safety device
Operating temperature Open °F266± 14.4
Close °F 174.2 ± 27
Run capacitor VAC, µF 440 V , 4 µF
Heater Ass'y (Aux. Heater)
Model AH - 2.4THS3632
2.4 / 1.94
Input (230 / 208 V) KW
Protective thermostat CS- 12AL OFF 122 ± 6°F, ON 104 ± 10°F
Thermo fuse SF96U Cut - off 205 ± 4°F
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows ... Fins per inch 3 ... 14.9
Face area ft.
2
(m
2
) 3.51 (0.326)
Auto louver motor
Model No. MT8 - 3C
Auto louver motor ... Rated V, W, rpm 240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 °F) 16,430 ± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE
BRW - WHT : 61.05 , ORG - YEL : 13.23
WHT - VLT : 9.955 , YEL - BLK : 19.25
VLT - ORG : 9.576 , BLK - PNK : 10.81
Centrifugal (4 ... 5-29/32(150))
KFG4X - 101C6P
230 - 208 V / 1 phase / 60 Hz