1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No. KH3072R
Source 230 - 208 V / 1 phase / 60 Hz
Remote controller (Option) Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y CR - TH2672
Control circuit fuse 250 V, 5 A
Fan Cross-flow
Number ... Dia. and length in. (mm) 1 ... O.D. 4-13/18 (120), L46 (1,170)
Fan motor
Model SGF4Q - 41D6P
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole ... r.p.m. (230 V, High) rpm 4 ... 1,275
Nominal output W 50
Coil resistance GRY - WHT : 125.4 , ORG - YEL : 23.93
(Ambient temperature 68 °F) WHT - VLT : 20.69 , YEL - PNK : 9.39
VLT - ORG : 11.31 ,
Safety device
Operating temperature Open °F 266 ± 14.4
Close °F 174.2 ± 26
Run capacitor VAC, µF 440 V , 4.5 µF
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows ... Fins per inch 2 ... 12.7
Face area ft.
2
(m
2
) 3.23 (0.3)
Louver Motor
Model M2EA24ZA01
Rating 208 to 230 V, 60 Hz
No. of pole ... rpm 8 ... 3
Output W 2.5
Coil resistance (Ambient temperature 68 °F) k 16.45 ± 8 %