13
-
HEC-DR8700
Error message indication (in Service Mode)
*Abnormal indications detected during operation are stored in a memory up to
seven. Seven abnormal indications stored can be confirmed in the service mode
(Older indications than the seven abnormal indications will be deleted sequentially).
To change over to the service mode, turn ON the POWER switch at the rear of the massager
while simultaneously pressing the OPERATION ON/OFF on a remote control.
(This operation should be started with the POWER switch turned OFF).
When the "QUICK" button is pressed three times with the OPERATION ON/OFF kept pressed,
the massager is placed in the service mode.
(When the massager is placed in the service mode, four lamps at the WHOLE BODY SENSOR
AUTOMATIC COURSES come on).
To reset the service mode, turn OFF the POWER switch.
<Resetting Procedure of Abnormal Indication Memory>
Press "REPEAT" button on the sensor controller to delete all
abnormal indication memory (When the STIFFNESS and TIMER
indicators are disappeared, all abnormal indication memory
have been deleted).
When the massager is placed in the service mode, the latest abnormal indication is displayed.
The ROLLER POSITION " (DOWN)" button of the remote control is used to display older
abnormal indications one by one, and " (UP)" to display newer abnormal indication one
by one (Following the sixth older (the oldest) indication, the latest indication is displayed again).
Up to seven abnormal indications are stored in a memory. In case of less than seven, since
there are not any abnormal indications, the STIFFNESS and TIMER indicators are disappeared
alternatively to indicate the state that abnormalities are not stored.
ROLLER POSITION "UP" "DOWN" button
OPERATION "ON/OFF" button
"QUICK" button (three times)
All abnormal indication
memory have been deleted
Latest
abnormality
"UP"
"DOWN"
Next older
abnormality
"UP"
"DOWN"
Second older
abnormality
"UP"
"DOWN"
Third older
abnormality
The oldest
abnormality
"UP"
"UP"
"DOWN"
"UP"
"DOWN"
"DOWN"
Fifth older
abnormality
"UP"
"DOWN"
Fourth older
abnormality
POWER switch "ON"