EasyManua.ls Logo

Sanyo PLC-XF45 - COMPUTER INPUT; Image Level Selection

Sanyo PLC-XF45
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-32-
9V
16V
6.25V
DELAY
ABNORMAL
VOL. DET.
LATCH
START
LOGIC
OC-RC
OSC
CONTROL
REF
OSC
3
2
1
ABNORMAL
TEMP. DET.
PC612
PC611
D652
D651
IC652
D655
T621
6
5
43
2
1
6
5
43
2
1
1
2
3
PROTECTION
89152
1
14
12
10456
11
7
Vcc
FET
FET
CONT
G (L)
G (H)
OUT
Vin
VOLTAGE CONTROL
ABNORMAL VOLTAGE DETECT
-6V
<FF>
STR-Z2156
Switching regulator
* NO POWER-2
Troubleshooting
IC632
If a temperature of this
frame reaches to 150˚C,
the IC632 will be shut
down.
If this Vcc voltage reaches to
abnormal voltage (exceeds
22V), the IC632 will be shut
down.
If this voltage reaches to
abnormal voltage (exceeds
6.8V), the IC632 will be shut
down.
Timing chart
Pin 4
OSC OUT
Pin 2
Pin 10
Check the signal at pin 5
of T621. (Switching power
IC output signal.)
Caution : "HOT" Circuit !
5
CHECK !
Check the switching regulator.

Other manuals for Sanyo PLC-XF45