29
Indoor Unit SAPK181GJA SAPK181MBA
Outdoor Unit SAPC181GA SAPC181MA
240V Single Phase 50Hz
RATING CAPACITY 5.15 kW
AIR FLOW RATE 760
m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP. °C OUTDOOR AMBIENT TEMP. °C
W.B. D.B. 30 35 40 45 50
TC 4.74 4.51 4.24 3.90 3.52
CM 1.69 1.81 2.07 2.33 2.59
21 SHC 3.14 3.02 2.87 2.70 2.51
15 23 SHC 3.49 3.37 3.23 3.06 2.86
25 SHC 3.85 3.73 3.58 3.41 3.22
27 SHC 4.20 4.08 3.94 3.77 3.52
29 SHC 4.56 4.44 4.24 3.90 3.52
31 SHC 4.74 4.51 4.24 3.90 3.52
TC 5.08 4.84 4.55 4.19 3.78
CM 1.73 1.86 2.12 2.38 2.64
21 SHC 2.77 2.65 2.51 2.34 2.15
17 23 SHC 3.13 3.01 2.86 2.69 2.50
25 SHC 3.48 3.36 3.22 3.05 2.86
27 SHC 3.84 3.72 3.57 3.40 3.21
29 SHC 4.19 4.07 3.93 3.76 3.56
31 SHC 4.55 4.43 4.28 4.11 3.78
TC 5.41 # 5.15 4.84 4.45 4.02
CM 1.79 1.92 2.18 2.45 2.71
21 SHC 2.39 2.27 2.13 1.95 1.77
19 23 SHC 2.74 2.62 2.48 2.31 2.12
25 SHC 3.10 2.98 2.84 2.66 2.47
27 SHC 3.45 3.33 3.19 3.02 2.83
29 SHC 3.81 3.69 3.55 3.37 3.18
31 SHC 4.16 4.04 3.90 3.73 3.54
TC 5.73 5.46 5.13 4.72 4.26
CM 1.84 1.97 2.24 2.51 2.78
23 SHC 2.35 2.23 2.09 1.92 1.74
21 25 SHC 2.71 2.59 2.45 2.28 2.09
27 SHC 3.06 2.94 2.80 2.63 2.45
29 SHC 3.41 3.30 3.16 2.99 2.80
31 SHC 3.77 3.65 3.51 3.34 3.16
TC 6.07 5.73 5.37 4.99 4.52
CM 1.89 2.02 2.30 2.57 2.84
23 25 SHC 2.28 2.15 2.01 1.86 1.69
27 SHC 2.64 2.50 2.36 2.22 2.04
29 SHC 2.99 2.86 2.71 2.57 2.40
31 SHC 3.35 3.21 3.07 2.93 2.75
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.