EasyManua.ls Logo

Sanyo SAP-K161GJA - Page 33

Sanyo SAP-K161GJA
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
Indoor Unit SAPK181GJA SAPK181MBA
Outdoor Unit SAPC181JA SAPC181BA
220V Single Phase 60Hz
RATING CAPACITY 5.15 kW
AIR FLOW RATE 760
m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP. °C OUTDOOR AMBIENT TEMP. °C
W.B. D.B. 30 35 40 45 50
TC 4.74 4.51 4.24 3.90 3.52
CM 1.32 1.42 1.60 1.78 1.96
21 SHC 3.13 3.01 2.87 2.70 2.51
15 23 SHC 3.49 3.37 3.22 3.05 2.86
25 SHC 3.84 3.72 3.58 3.41 3.22
27 SHC 4.20 4.08 3.93 3.76 3.52
29 SHC 4.55 4.43 4.24 3.90 3.52
31 SHC 4.74 4.51 4.24 3.90 3.52
TC 5.08 4.84 4.55 4.19 3.78
CM 1.36 1.46 1.64 1.83 2.01
21 SHC 2.77 2.65 2.51 2.33 2.14
17 23 SHC 3.13 3.00 2.86 2.69 2.50
25 SHC 3.48 3.36 3.22 3.04 2.85
27 SHC 3.84 3.71 3.57 3.40 3.21
29 SHC 4.19 4.07 3.93 3.75 3.56
31 SHC 4.55 4.42 4.28 4.11 3.78
TC 5.41 # 5.15 4.84 4.45 4.02
CM 1.40 1.50 1.69 1.88 2.06
21 SHC 2.39 2.26 2.12 1.95 1.76
19 23 SHC 2.74 2.62 2.48 2.31 2.12
25 SHC 3.10 2.97 2.83 2.66 2.47
27 SHC 3.45 3.33 3.19 3.01 2.83
29 SHC 3.81 3.68 3.54 3.37 3.18
31 SHC 4.16 4.04 3.90 3.72 3.54
TC 5.73 5.46 5.13 4.72 4.26
CM 1.44 1.54 1.73 1.92 2.11
23 SHC 2.35 2.23 2.09 1.92 1.73
21 25 SHC 2.70 2.58 2.44 2.27 2.09
27 SHC 3.06 2.94 2.80 2.63 2.44
29 SHC 3.41 3.29 3.15 2.98 2.80
31 SHC 3.77 3.65 3.51 3.34 3.15
TC 6.07 5.73 5.37 4.99 4.52
CM 1.48 1.58 1.78 1.97 2.16
23 25 SHC 2.28 2.14 2.00 1.86 1.69
27 SHC 2.64 2.50 2.36 2.21 2.04
29 SHC 2.99 2.85 2.71 2.57 2.40
31 SHC 3.35 3.21 3.07 2.92 2.75
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.

Table of Contents

Related product manuals