4. REFRIGERANT FLOW DIAGRAM
12
Capillary tube
Capillary for
liquid injection
Compressor
Accumulator
Wide tube
service
valve
Wide tube
O.D.
ø12.7 mm
(1/2 ")
Narrow
tube
service
valve
Narrow tube
O.D.
ø6.35 mm
(1/4")
Condenser
Indoor Unit Outdoor Unit
Evaporator
Indoor Unit SAPK181AA Outdoor Unit SAPC181AA
Compressor
Wide tube
service
valve
Wide tube
O.D.
ø15.88 mm
(5/8 ")
Narrow
tube
service
valve
Narrow tube
O.D.
ø6.35 mm
(1/4")
Evaporator
Capillary for
liquid injection
Indoor Unit Outdoor Unit
Muffler
Capillary tube
Condenser
Strainer
Accumulator
Indoor Unit SAPK241AA Outdoor Unit SAPC241AA
Insulation of Refrigerant Tubing
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
IMPORTANT
CAUTION
Wide tube
Thickness:
Min. 8 mm
Insulation
Narrow tube
Thickness:
Min. 8 mm