6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 240V Single phase 50Hz
Rating Conditions Running Amps. A 0.40 0.50 12.30 13.2
Power Input kW 0.080 0.118 2.632 2.83
Full Load Conditions Running Amps. A 0.40 0.50 14.80 15.7
Power Input kW 0.080 0.118 3.262 3.46
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit SAPK241AA
Outdoor Unit SAPC241AA
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 240V Single phase 50Hz
Rating Conditions Running Amps. A 0.38 0.50 8.72 9.6
Power Input kW 0.073 0.119 1.988 2.18
Full Load Conditions Running Amps. A 0.38 0.50 10.52 11.4
Power Input kW 0.073 0.119 2.478 2.67
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit SAPK181AA
Outdoor Unit SAPC181AA