Loading...
29
Indoor Unit SAPK121GJA
Outdoor Unit SAPC121JA
220V Single Phase 60Hz
RATING CAPACITY 3.40 kW
AIR FLOW RATE 470
m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP. °C OUTDOOR AMBIENT TEMP. °C
W.B. D.B. 30 35 40 43
TC 3.13 2.98 2.80 2.58
CM 1.01 1.09 1.13 1.31
21 SHC 2.07 1.99 1.90 1.79
15 23 SHC 2.31 2.23 2.13 2.02
25 SHC 2.54 2.46 2.36 2.25
27 SHC 2.77 2.69 2.59 2.48
29 SHC 3.00 2.92 2.80 2.58
31 SHC 3.13 2.98 2.80 2.58
TC 3.36 3.20 3.00 2.76
CM 1.04 1.12 1.16 1.34
21 SHC 1.84 1.76 1.66 1.55
17 23 SHC 2.07 1.99 1.89 1.78
25 SHC 2.30 2.22 2.13 2.01
27 SHC 2.53 2.45 2.36 2.24
29 SHC 2.76 2.68 2.59 2.47
31 SHC 3.00 2.91 2.82 2.71
TC 3.57 # 3.40 3.20 2.94
CM 1.07 1.15 1.20 1.38
21 SHC 1.59 1.51 1.41 1.30
19 23 SHC 1.82 1.74 1.64 1.53
25 SHC 2.05 1.97 1.88 1.76
27 SHC 2.28 2.20 2.11 1.99
29 SHC 2.51 2.43 2.34 2.22
31 SHC 2.74 2.66 2.57 2.46
TC 3.78 3.60 3.39 3.12
CM 1.10 1.18 1.23 1.42
23 SHC 1.56 1.48 1.39 1.28
21 25 SHC 1.79 1.71 1.62 1.51
27 SHC 2.03 1.95 1.85 1.74
29 SHC 2.26 2.18 2.09 1.97
31 SHC 2.49 2.41 2.32 2.20
TC 4.01 3.78 3.54 3.29
CM 1.13 1.21 1.27 1.45
23 25 SHC 1.52 1.43 1.33 1.24
27 SHC 1.75 1.66 1.57 1.47
29 SHC 1.98 1.89 1.80 1.70
31 SHC 2.21 2.12 2.03 1.93
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.