EasyManua.ls Logo

Sanyo SAP–K91A - Other Component Specifications

Sanyo SAP–K91A
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
2-3. Other Component Specifications
Power Relay (PR) G7L-2A-TUB-55
Coil rating AC 200240V, 50/60Hz
Coil resistance (at 23°C) 21 ± 15%
Contact rating AC 220V, 25A
Outdoor Unit SAPCM1821A
Thermistor (Room sensor) DTN-TKS128B
Resistance k 25°C 5.0 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance k 0°C 15.0 ± 2%
Transformer (TR) ATR-J105
Rating Primary AC 230V, 50/60Hz
Secondary 19V, 0.526A
Capacity 10VA
Coil resistance (at 21°C) Primary (WHT – WHT): 205 ± 10%
Secondary (BRN – BRN): 2.0 ± 10%
Thermal cut-off temp. 150°C
Indoor Unit SAPK91A

Table of Contents