EasyManua.ls Logo

Sanyo SAP–K91A - 10. TROUBLESHOOTING; 10-1. Check before and after troubleshooting

Sanyo SAP–K91A
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10. TROUBLESHOOTING
10-1. Check before and after
troubleshooting
10-1-1. Check power supply wiring.
Check that power supply wires are correctly connect-
ed to terminals No.1 and No.2 on the terminal plate in
the outdoor unit.
10-1-2. Check inter-unit wiring.
Check that inter-unit wiring is correctly connected to
the indoor unit from the outdoor unit.
10-1-3. Check power supply.
Check that voltage is in specified range
(±10% of the rating).
Check that power is being supplied.
10-1-4. Check lead wires and connectors in
indoor and outdoor units.
Check that coating of lead wires is not damaged.
Check that lead wires and connectors are firmly con-
nected.
Check that wiring is correct.
21
WARNING
Hazardous voltage can cause ELECTRIC
SHOCK or DEATH. Disconnect power or turn
off circuit breaker before you start checking
or servicing.
Ground
Ground
Ground
Outdoor unit
Ground
Indoor Unit A
Indoor Unit B
4
5
6
7
8
9
10
11
12
1
2
3
4
1
2
3
4
1
2
3
Power supply:
50Hz
Single-phase,
240V
Ground
Inter-unit
power wiring