25
E. Check fuse on the indoor PCB Ass'y.
F. Check TIMER on the remote control unit.
OK
OK
Check fuse on indoor PCB Ass'y
for continuity. (F)
Check operation lamp to see
if light is ON.
Light is OFF
Measure resistance of primary and
secondary winding of transformer.
(TR)
Indoor PCB Ass'y or switch Ass'y is
defective.
OK
OK
Measure resistance of indoor fan
motor winding.
(FM)
Measure resistance of flap motor
winding. (FLP)
OK
Measure coil resistance of power
relay in outdoor unit.
(PRA, PRB)
Replace the fuse.
If fuse has been blown,
Timer is turned ON. Check to see
if is displayed on remote
control.
YES
Cancel the timer mode.
ON