EasyManua.ls Logo

Sanyo SAP–K92A - Page 49

Sanyo SAP–K92A
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C. Check "OPERATION selector" switch in the indoor unit.
D. Check transformer in indoor unit.
E. Check fuse on the indoor PCB Ass'y.
F. Check TIMER on the remote control unit.
Timer is turned ON. Check to see
if is displayed on remote
control.
YES
Cancel the timer mode.
ON
OK
OK
Check fuse on indoor PCB Ass'y
for continuity. (F01)
Check operation lamp to see
if light is ON.
Light is OFF
Measure resistance of primary and
secondary winding of transformer.
(TR)
Indoor PCB Ass'y or switch Ass'y is
defective.
OK
OK
Measure resistance of indoor and/or
fan motor winding.
(FM)
Measure resistance of compressor
motor winding. (CM)
OK
Measure coil resistance of power
relay. (PR)
Replace the fuse.
If fuse has been blown,
Measure resistance of primary and
secondary winding.
(TR)
YES
NO
OPERATION selector switch is set
in ON position.
Set OPERATION selector switch
to ON.
Indoor PCB Ass'y is defective.
46

Related product manuals