4
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Power Source 220 – 240 V Single phase 50 Hz
Voltage rating V 220 / 230 / 240
Cooling
Capacity
kW 5.15 / 5.15 / 5.00
BTU/h 17,600 / 17,600 / 17,100
Air circulation (High) m3/h 760
Moisture removal (High) Liters/h 2.7
Available voltage range V 198 to 264
Running amperes A 9.5 / 9.5 / 10.1
Power input W 2,000 / 2,030 / 2,130
Power factor % 96 / 93 / 88
C.O.P. W/W 2.58 / 2.54 / 2.35
Compressor locked rotor amperes A 50 / 53 / 55
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer 1-hour OFF / 12-hour ON or OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto (Hi, Lo)
Airflow direction (Indoor )
Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R22 / 1,350
Refrigerant control Capillary tube
Operation sound
Indoor – Hi / Me / Lo dB-A 41 / 38 / 36
Outdoor – Hi dB-A 53
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant tube
Narrow tube mm (in.) 6.35 (1/4)
diameter
Wide tube mm (in.) 12.7 (1/2)
Refrigerant tube kit / Accessories Optional / Hanging wall bracket
Indoor Unit Outdoor Unit
Unit dimensions Height mm 285 630
Width mm 995 810
Depth mm 196 275
Package dimensions Height mm 276 704
Width mm 1,070 953
Depth mm 363 396
Weight Net
kg 12.0 49.0
Shipping
kg 15.0 53.5
Shipping volume m3 0.11 0.25
Dimensions & Weight Features Electrical Rating Performance
Indoor Unit SAP–K182A
Outdoor Unit SAP–C182A