FILE NO.
TECHNICAL DATA
&
SERVICE MANUAL
85464869177001 REFERENCE NO. TD831077
OUTDOOR MODEL No. PRODUCT CODE No. APPLICABLE INDOOR MODEL No. V / ø / Hz
SPW-CR1503GDYH8 85401575
SPW - K(R) · AS(R) · S(R)· UR · F(R)· FM(R) · SLR
93GH56
OUTDOOR
SPW-CR1903GDYH8 85401576
SPW - X(R) · K(R) · AS(R) · S(R)· UR · F(R)· FM(R) · SLR
123GH56
380 - 415 / 3 ø / 50
SPW-CR703GDCH8 85401579
SPW - X(R) · K(R) · TR · S(R)· UR · F(R)· FM(R) · SLR
183GH56
SPW-CR903GDCH8 85401580
SPW - X(R) · TR · S(R) · UR · D(R) · F(R)· FM(R) · SLR
253GH56
INDOOR
SPW-C1503GDYH8 85401573
SPW - X(R) · TR · UR · D(R)
363GH56
220 - 240 / 1 ø / 50
SPW-C1903GDYH8 85401574
SPW - X(R) · TR · UR · D(R)
483GH56
SPW-C703GDCH8 85401577
SPW - DR
763GH56
SPW-C903GDCH8 85401578
SPW - DR
963GH56
R407C
&
R22

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sanyo SPW-CR903GDCH8 and is the answer not in the manual?

Sanyo SPW-CR903GDCH8 Specifications

General IconGeneral
BrandSanyo
ModelSPW-CR903GDCH8
CategoryAir Conditioner
LanguageEnglish

Summary

Important Safety and Operation Guidelines

Please Read Before Starting

Essential steps for safe installation and trouble-free operation of the air conditioning system.

When Connecting Refrigerant Tubing

Instructions for safely connecting refrigerant tubing, including leak checks.

Density Limit Check

Density Limit Requirements

Ensuring refrigerant gas density does not exceed set limits to prevent suffocation risk.

Design of W-ECO MULTI SYSTEM

Model Selecting and Capacity Calculation

Procedure for selecting models and calculating system capacity based on various factors.

Electrical Wiring

Precautions and recommendations for wiring, including wire size and diagram.

Installation Instructions

Guidelines for selecting installation sites, transporting, and installing indoor and outdoor units.

Test Run and Others

Test Run

Detailed procedures for performing test runs, including address setting and operation checks.

Installation Standards

Standards for gas leak inspection, density limit checks, and precautions for new refrigerants.

Processes and Functions

Protection Controls

Overview of various protection mechanisms including temperature and current controls.

Backup Operation

Procedures for backup operation when a unit or compressor is faulty.

Replacement of Main Units

Compressors

Procedures for judging compressor replacement needs and detailed steps for replacement.

Indoor Units

Procedures for refrigerant recovery and operation when faults occur in indoor units.

Electrical Data

Outdoor Unit

Electrical specifications and wiring diagrams for outdoor units (R407C and R22).