Sartorius Gem GE1302 Specifications

General IconGeneral
Maximum Capacity1300 g
Readability0.01 g
CalibrationExternal
DisplayLCD
Repeatability (Std. Dev.)0.01 g
Linearity±0.02 g
Stabilization Time (typical)2 seconds
Power SupplyAC Adapter
Weighing Unitsg, ct, oz, dwt
InterfaceRS232
Operating Temperature10°C to 30°C
Weight2.5kg

Summary

Menu Code Settings (Rel 19.41 Version)

Menu 1: Calibration and Adjustment

Controls access to calibration and adjustment functions, including auto zero.

Menu 9: Factory Reset

Restores the balance to its original factory settings and resets SBI mode.

Activating the BPI Mode

Balances/Scales with Strain Gauge Systems

Zero-point Offset Value

Adjusting the Zero-point Offset Value

Explains the process of adjusting the zero-point offset using a DVM and specific components.

Repeatability (Standard Deviation)

Off-center Error

Checking the Off-center Error

Describes how to test for off-center loading errors by placing weights in different positions.

Checking Off-center Loading Tolerances

Explains OIML guidelines for off-center loading tests and placement of test weights.

Adjusting the Off-center Error

Details the method for adjusting off-center errors by filing thin parts on the load receptor.

Checking the Off-Center Error

Details how to test off-center errors for different pan types using specific models.

Span Adjustment

Span Adjustment Procedure

Explains how to perform span adjustment using the operating menu and calibration weights.

Adjusting Linearity

Checking the Linearity

Outlines the process for checking linearity using specific weighing steps and tolerances.

Adjusting the Linearity

Describes using service software to adjust the balance linearity after checking.

Balances/Scales with Double Lever Systems

Repeatability (Standard deviation)

Checking the Repeatability

Guides on performing repeatability tests using specified weights and calculating the standard deviation.

Adjusting the Off-Center Error

Procedure for Adjusting Off-Center Error (Double-Lever System)

Explains the 3-point measurement and adjustment process for double-lever systems.

3-point Measurement for Off-Center Error

Details the 3-point measurement method to determine and adjust off-center loading errors.

Off-Center Error Adjustment by Filing

Describes adjusting off-center errors by filing thin parts on specific models.

Opening and Closing the Balance/Scale

Replacing the PCB

PCB Replacement Procedure

Details the process of replacing the main PCB, including data backup and reprogramming.

Replacing the Data Output Port

Error Codes